Hanuman Nagar, Nagpur, Maharashtra
GST No. 27BRIPK9782P1ZN
Approx. Rs 7 Lakh / PieceGet Latest Price
Product BrochureProduct Details:Power (kVA) | 100 kVA |
Brand | TATA Powerlux |
Model | TPDG100 (DG Model ) |
Phase | Three Phase |
Fuel Tank Capacity | 205 L |
Fuel type | Diesel |
Dimension | 3700 x 1200 x 1600 mm (L x B x H) |
No Of Cylinder | 6 |
Rated Current | 139 Amp |
Weight | 1710 Kg |
Power kW | 80 kW |
Engine Model | 697TC52 |
Brake Horsepower | 125 BHP |
Aspiration | TCIC |
Cooling System | Liquid |
Noise Level | Silent or Soundproof |
Other Essentials:
Engines are tested as per IS 10000 standards
Superior Quality alternators are used confirming to IS13364, IS4722 & BS5000 standards
Technologically advanced control panels with deep sea/ Procom controller
Heavy, Robust and sound efficient DG gets confirming to CPCB-II norms & rule 95 of environment protection of GSR no of 771 (E) & GSR 232 (E)
How to Calculate Load:
Put on only those equipments which you want to run on the Powerlux Silent Generator.
Go near the distribution box where you''ll find four colored cables; Red, Yellow, Blue & Black.
Put the clamp meter around the Red, Yellow & Blue cable one by one and note down the ampere rating. Now add the numbers in case of single phase requirement or pick the highest in case of three phase requirement.
Select your kVA from the above given ampere chart and see under which rating your requirement falls.
Note:
After putting the clamp meter around the cable; turn off and on the heavy machines/equipments for better calculation. Also always select a rating 20% higher to your load for long term usage.
All of the above silent genset range is made to perform at 1500 RPM
Rated current output is at 100% load. 0.8 power factor
Weight mentioned is approximate
Product innovation is a continuous process; hence data given is subject to change without any prior notice.
Detailed technical specification sheet separately available for each rating in soft copy
Approx. Rs 7 Lakh / PieceGet Latest Price
Product BrochureProduct Details:Power | 66 kW |
Power (kVA) | 82.5 kVA |
Voltage | 415 V |
Brand | TATA Powerlux |
Model | TPDG82.5 |
Phase | Three Phase |
Fuel Type | Diesel |
Fuel Tank Capacity | 205 L |
Cooling System | Liquid |
Rated Current | 114 Amp at 415 V |
Engine Model | 697TC51 |
Dimension | 3200 x 1250 x 1500 mm |
No Of Cylinder | 6 |
Brake Horsepower | 109 BHP |
Weight | 1620 Kg |
Other Essentials:
Engines are tested as per IS 10000 standards
Superior Quality alternators are used confirming to IS13364, IS4722 & BS5000 standards
Technologically advanced control panels with deep sea/ Procom controller
Heavy, Robust and sound efficient DG gets confirming to CPCB-II norms & rule 95 of environment protection of GSR no of 771 (E) & GSR 232 (E)
How to Calculate Load:
Put on only those equipments which you want to run on the Powerlux Silent Generator.
Go near the distribution box where you''ll find four colored cables; Red, Yellow, Blue & Black.
Put the clamp meter around the Red, Yellow & Blue cable one by one and note down the ampere rating. Now add the numbers in case of single phase requirement or pick the highest in case of three phase requirement.
Select your kVA from the above given ampere chart and see under which rating your requirement falls.
Note:
After putting the clamp meter around the cable; turn off and on the heavy machines/equipments for better calculation. Also always select a rating 20% higher to your load for long term usage.
All of the above silent genset range is made to perform at 1500 RPM
Rated current output is at 100% load. 0.8 power factor
Weight mentioned is approximate
Product innovation is a continuous process; hence data given is subject to change without any prior notice.
Detailed technical specification sheet separately available for each rating in soft copy
Approx. Rs 9 Lakh / PieceGet Latest Price
Product BrochureProduct Details:Power | 32 kW |
Power (kVA) | 40 KVA |
Brand | TATA Powerlux |
Voltage | 415 V |
Phase | Three Phase |
Fuel Tank Capacity | 135 L |
Fuel Type | Diesel |
Rated Current | 174 Amp at 230 V, 56 Amp at 415 V |
Aspiration | TCIC |
Dg Set Model | TPDG40 |
Brake Horsepower | 63 BHP |
Engine Model | 497TC76 |
Dimension | 2800 x 1100 x 1540 mm |
Weight | 1242 Kg |
No Of Cylinder | 4 |
Other Essentials:
Engines are tested as per BS5514, IS: 10002 and IS01000B respectively.
Superior quality alternators are used confirming to lS13364, IS4722 & BS5000 standards.
Technologically advanced control panels with Deep-sea / Procom controller. Heavy, robust and sound efficient DG sets confirming to CPCB-II norms & Rule 95 of environment protection of GSR no of 771(E) & GSR 232(E).
How to Calculate Load:
Put on only those equipment''s which you want to run on the Powerlux Silent Generator.
Go near the distribution box where you''ll find four colored cables; Red, Yellow, Blue & Black.
Put the clamp meter around the Red, Yellow & Blue cable one by one and note down the ampere rating.
Now add the numbers in case of single phase requirement or pick the highest in case of three phase requirement.
Select your kVA from the above given ampere chart and see under which rating your requirement falls.
Note:
After putting the clamp meter around the cable; turn off and on the heavy machines/equipment''s for better calculation. Also always select a rating 20% higher to your load for long term usage.
AII of the above silent genset range is made to perform at 1500 rpm.
Rated current output is at 100% load.(0.8 Power Factor).
Weight mentioned is approximate.
Product innovation is a continuous process; hence data given is subject to change without any prior notice.
Detailed technical specification sheet separately available for each rating in soft copy.
Approx. Rs 7.8 Lakh / PieceGet Latest Price
Product BrochureProduct Details:Power (kVA) | 45 kVA/36 kW |
Brand | TATA Powerlux |
Model | TPDG45 (Dg Set Model ) |
Phase | Three Phase |
Fuel Consumption (at 100% Load) | 0.8 power factor |
Fuel Tank Capacity | 135 L |
Weight | 1254 Kg |
Brake Horsepower | 75 BHP |
Noise Level | Silent or Soundproof |
Engine Model | 497TC75 |
Rated Current | 63 Amp at 415 V |
Fuel type | Diesel |
Dimension | 2800 x 1100 x 1540 mm |
Other Essentials:
Engines are tested as per IS 10000 standards
Superior Quality alternators are used confirming to IS13364, IS4722 & BS5000 standards
Technologically advanced control panels with deep sea/ Procom controller
Heavy, Robust and sound efficient DG gets confirming to CPCB-II norms & rule 95 of environment protection of GSR no of 771 (E) & GSR 232 (E)
How to Calculate Load:
Put on only those equipments which you want to run on the Powerlux Silent Generator.
Go near the distribution box where you''ll find four colored cables; Red, Yellow, Blue & Black.
Put the clamp meter around the Red, Yellow & Blue cable one by one and note down the ampere rating. Now add the numbers in case of single phase requirement or pick the highest in case of three phase requirement.
Select your kVA from the above given ampere chart and see under which rating your requirement falls.
Note:
After putting the clamp meter around the cable; turn off and on the heavy machines/equipments for better calculation. Also always select a rating 20% higher to your load for long term usage.
All of the above silent genset range is made to perform at 1500 RPM
Rated current output is at 100% load. 0.8 power factor
Weight mentioned is approximate
Product innovation is a continuous process; hence data given is subject to change without any prior notice.
Detailed technical specification sheet separately available for each rating in soft copy
Approx. Rs 7 Lakh / PieceGet Latest Price
Product BrochureProduct Details:Power | 28 kW |
Power (kVA) | 35 kVA |
Voltage | 415 V |
Brand | TATA Powerlux |
Phase | Three Phase |
Fuel Tank Capacity | 135 L |
Rated Current | 152 Amp at 230 V, 49 Amp at 415 V |
Aspiration | TCIC |
Dg Set Model | TPDG35 |
No Of Cylinder | 4 |
Brake Horsepower | 56 BHP |
Weight | 1236 Kg |
Cable (alumn.): | 2C-120/3.5C-50 Sq. mm |
Engine Model | 497TC77 |
Dimension | 2800 x 1100 x 1540 mm |
Other Essentials:
Engines are tested as per BS5514, IS: 10002 and IS01000B respectively.
Superior quality alternators are used confirming to lS13364, IS4722 & BS5000 standards.
Technologically advanced control panels with Deep-sea / Procom controller. Heavy, robust and sound efficient DG sets confirming to CPCB-II norms & Rule 95 of environment protection of GSR no of 771(E) & GSR 232(E).
How to Calculate Load:
Put on only those equipment''s which you want to run on the Powerlux Silent Generator.
Go near the distribution box where you''ll find four colored cables; Red, Yellow, Blue & Black.
Put the clamp meter around the Red, Yellow & Blue cable one by one and note down the ampere rating.
Now add the numbers in case of single phase requirement or pick the highest in case of three phase requirement.
Select your kVA from the above given ampere chart and see under which rating your requirement falls.
Note:
After putting the clamp meter around the cable; turn off and on the heavy machines/equipment''s for better calculation. Also always select a rating 20% higher to your load for long term usage.
AII of the above silent genset range is made to perform at 1500 rpm.
Rated current output is at 100% load.(0.8 Power Factor).
Weight mentioned is approximate.
Product innovation is a continuous process; hence data given is subject to change without any prior notice.
Detailed technical specification sheet separately available for each rating in soft copy.
Approx. Rs 8.7 Lakh / PieceGet Latest Price
Product BrochureProduct Details:Power (kVA) | 50 kVA/40 kW |
Brand | TATA Powerlux |
Model | TPDG50 (Dg Set Model ) |
Phase | Three Phase |
Fuel Consumption (at 100% Load) | 0.8 power factor |
Fuel Tank Capacity | 135 L |
Rated Current | 70 Amp at 415 V |
Fuel type | Diesel |
Noise Level | Silent or Soundproof |
Engine Model | 497TC75 |
Weight | 1272 Kg |
Dimension | 2800 x 1100 x 1540 mm |
Brake Horsepower | 75 BHP |
No Of Cylinder | 4 |
Other Essentials:
Engines are tested as per IS 10000 standards
Superior Quality alternators are used confirming to IS13364, IS4722 & BS5000 standards
Technologically advanced control panels with deep sea/ Procom controller
Heavy, Robust and sound efficient DG gets confirming to CPCB-II norms & rule 95 of environment protection of GSR no of 771 (E) & GSR 232 (E)
How to Calculate Load:
Put on only those equipments which you want to run on the Powerlux Silent Generator.
Go near the distribution box where you''ll find four colored cables; Red, Yellow, Blue & Black.
Put the clamp meter around the Red, Yellow & Blue cable one by one and note down the ampere rating. Now add the numbers in case of single phase requirement or pick the highest in case of three phase requirement.
Select your kVA from the above given ampere chart and see under which rating your requirement falls.
Note:
After putting the clamp meter around the cable; turn off and on the heavy machines/equipments for better calculation. Also always select a rating 20% higher to your load for long term usage.
All of the above silent genset range is made to perform at 1500 RPM
Rated current output is at 100% load. 0.8 power factor
Weight mentioned is approximate
Product innovation is a continuous process; hence data given is subject to change without any prior notice.
Detailed technical specification sheet separately available for each rating in soft copy
Approx. Rs 8 Lakh / PieceGet Latest Price
Product Details:Power (kVA) | 20 kVA |
Brand | TATA Powerlux |
Model | TPDG25 (DG Model ) |
Phase | Three Phase |
Fuel Tank Capacity | 135 L |
Number Of Cylinder | 4 |
Cable | 2C-70/3.5C-25 |
Rated Current | 108A at 230 V, 35A at 415 V |
Engine Model | 4SPTC25 |
Brake Horsepower | 40 BHP |
Noise Level | Silent or Soundproof |
Dimension | 2500 x 1100 x 1540 mm |
Cooling System | Water Cooling |
Weight | 1080 Kg |
Material | MS |
Aspiration | TCIC |
Other Essentials:
Engines are tested as per IS 10000 standards
Superior Quality alternators are used confirming to IS13364, IS4722 & BS5000 standards
Technologically advanced control panels with deep sea/ Procom controller
Heavy, Robust and sound efficient DG gets confirming to CPCB-II norms & rule 95 of environment protection of GSR no of 771 (E) & GSR 232 (E)
How to Calculate Load:
Put on only those equipments which you want to run on the Powerlux Silent Generator.
Go near the distribution box where you''ll find four colored cables; Red, Yellow, Blue & Black.
Put the clamp meter around the Red, Yellow & Blue cable one by one and note down the ampere rating. Now add the numbers in case of single phase requirement or pick the highest in case of three phase requirement.
Select your kVA from the above given ampere chart and see under which rating your requirement falls.
Note:
After putting the clamp meter around the cable; turn off and on the heavy machines/equipments for better calculation. Also always select a rating 20% higher to your load for long term usage.
All of the above silent genset range is made to perform at 1500 RPM
Rated current output is at 100% load. 0.8 power factor
Weight mentioned is approximate
Product innovation is a continuous process; hence data given is subject to change without any prior notice.
Detailed technical specification sheet separately available for each rating in soft copy
Approx. Rs 4.8 Lakh / PieceGet Latest Price
Product Details:Minimum Order Quantity | 1 Piece |
Power (kVA) | 62.5 kVA/ 50 kW |
Brand | TATA |
Model | TPDG62.5 (Dg Set Model ) |
Phase | 3 Phase |
Fuel Tank Capacity | 150 L |
Engine Model | 497 TC |
Rated Current | 87 Amps at 415V |
Noise Level | Silent or Soundproof |
Dimension | 2600 x 1100 x 1550 mm |
Brake Horsepower | BHP 90 |
Weight | 1395 Kg |
No Of Cylinder | 4 |
Cable Alumn | 3.5C-70 Sq. mm. |
Fuel type | Diesel |
They are suitable for small & medium Industries, Rice Mills, Cold storages, Stone Crushers, Railways, Defence, Telecom, IT Segment, Hospitals, Clinics, Schools, Colleges, Cinema Halls, Shopping Malls, Residential Apartments etc.
Approx. Rs 1.2 Lakh / PieceGet Latest Price
Product Details:Power (kVA) | 125 kVA |
Usage/Application | Power |
Brand | TATA Powerlux |
Model | TPDG100 (DG Model ) |
Phase | Three Phase |
Output Voltage | 415 V |
Fuel Consumption (at 100% Load) | 0.8 power factor |
Fuel Tank Capacity | 205 L |
Material | MS |
Aluminium Cable | 150 Sq mm |
Noise Level | Silent or Soundproof |
Cooling System | Water Cooling |
Brake Horsepower | 154 BHP |
Emission | CPCB II |
Other Essentials:
Engines are tested as per IS 10000 standards
Superior Quality alternators are used confirming to IS13364, IS4722 & BS5000 standards
Technologically advanced control panels with deep sea/ Procom controller
Heavy, Robust and sound efficient DG gets confirming to CPCB-II norms & rule 95 of environment protection of GSR no of 771 (E) & GSR 232 (E)
How to Calculate Load:
Put on only those equipments which you want to run on the Powerlux Silent Generator.
Go near the distribution box where you''ll find four colored cables; Red, Yellow, Blue & Black.
Put the clamp meter around the Red, Yellow & Blue cable one by one and note down the ampere rating. Now add the numbers in case of single phase requirement or pick the highest in case of three phase requirement.
Select your kVA from the above given ampere chart and see under which rating your requirement falls.
Note:
After putting the clamp meter around the cable; turn off and on the heavy machines/equipments for better calculation. Also always select a rating 20% higher to your load for long term usage.
All of the above silent genset range is made to perform at 1500 RPM
Rated current output is at 100% load. 0.8 power factor
Weight mentioned is approximate
Product innovation is a continuous process; hence data given is subject to change without any prior notice.
Detailed technical specification sheet separately available for each rating in soft copy
Approx. Rs 5.25 Lakh / PieceGet Latest Price
Product Details:Minimum Order Quantity | 1 Piece |
Power (kVA) | 82.5kVA/66 kW |
Brand | TATA generator |
Fuel Tank Capacity | 260 L |
Weight | 2040 Kg |
Fuel type | Diesel |
Engine Model | 697 TC |
Brake Horsepower | 109 BHP |
No Of Cylinder | 4 |
Dimension | 3200 x 1200 x 1510 mm |
Rated Current | 104 Amp at 415 V |
Cooling System | Water cooled |
Dg Set Model | TPDG75 |
Other Essentials:
Engines are tested as per IS 10000 standards
Superior Quality alternators are used confirming to IS13364, IS4722 & BS5000 standards
Technologically advanced control panels with deep sea/ Procom controller
Heavy, Robust and sound efficient DG gets confirming to CPCB-II norms & rule 95 of environment protection of GSR no of 771 (E) & GSR 232 (E)
How to Calculate Load:
Put on only those equipments which you want to run on the Powerlux Silent Generator.
Go near the distribution box where you''ll find four colored cables; Red, Yellow, Blue & Black.
Put the clamp meter around the Red, Yellow & Blue cable one by one and note down the ampere rating. Now add the numbers in case of single phase requirement or pick the highest in case of three phase requirement.
Select your kVA from the above given ampere chart and see under which rating your requirement falls.
Note:
After putting the clamp meter around the cable; turn off and on the heavy machines/equipments for better calculation. Also always select a rating 20% higher to your load for long term usage.
All of the above silent genset range is made to perform at 1500 RPM
Rated current output is at 100% load. 0.8 power factor
Weight mentioned is approximate
Product innovation is a continuous process; hence data given is subject to change without any prior notice.
Detailed technical specification sheet separately available for each rating in soft copy
Approx. Rs 6.7 Lakh / PieceGet Latest Price
Product Details:Power (kVA) | 30 kVA / 24 kW |
Brand | TATA Powerlux |
Phase | Three Phase |
Fuel Tank Capacity | 135 L |
Engine Model | 4SPTC30 |
Weight | 1120 Kg |
Rated Current | 130 Amp at 230 V, 42 Amp at 415 V |
Brake Horsepower | 48 |
Cooling System | Liquid |
Aspiration | TCIC |
Dg Set Model | TPDG30 |
Cable | 2C-95/3.5C-35 Sq. mm. |
Dimension | 2500 x 1100 x 1540 mm |
No Of Cylinder | 4 |
Other Essentials:
Engines are tested as per BS5514, IS: 10002 and IS01000B respectively.
Superior quality alternators are used confirming to lS13364, IS4722 & BS5000 standards.
Technologically advanced control panels with Deep-sea / Procom controller. Heavy, robust and sound efficient DG sets confirming to CPCB-II norms & Rule 95 of environment protection of GSR no of 771(E) & GSR 232(E).
How to Calculate Load:
Put on only those equipment''s which you want to run on the Powerlux Silent Generator.
Go near the distribution box where you''ll find four colored cables; Red, Yellow, Blue & Black.
Put the clamp meter around the Red, Yellow & Blue cable one by one and note down the ampere rating.
Now add the numbers in case of single phase requirement or pick the highest in case of three phase requirement.
Select your kVA from the above given ampere chart and see under which rating your requirement falls.
Note:
After putting the clamp meter around the cable; turn off and on the heavy machines/equipment''s for better calculation. Also always select a rating 20% higher to your load for long term usage.
AII of the above silent genset range is made to perform at 1500 rpm.
Rated current output is at 100% load.(0.8 Power Factor).
Weight mentioned is approximate.
Product innovation is a continuous process; hence data given is subject to change without any prior notice.
Detailed technical specification sheet separately available for each rating in soft copy.