Hanuman Nagar, Nagpur, Maharashtra
GST No. 27BRIPK9782P1ZN
Approx. Rs 6 Lakh / PieceGet Latest Price
Product Details:Phase | 3-Phase |
Engine Make | Eicher |
Genset Brand | Eicher |
Power (kVA) | As Per Requirement |
On-site Service | Available |
AMC | Available |
Country of Origin | Made in India |
Features:
Approx. Rs 6.7 Lakh / PieceGet Latest Price
Product BrochureProduct Details:Power (kVA) | 25 KVA/20 KW |
Brand | Escorts Powerlux |
Voltage | 415 V |
Model | ELG 25(Dg Set Model ) |
Phase | Three Phase |
Fuel Type | Diesel |
Fuel Tank Capacity | 130 L |
Material | MS |
Noise Level | Silent or Soundproof |
Rated Current | 108 Amp at 230 V, 35 Amp at 415 V |
No Of Cylinders | 3 |
Weight | 832 Kg |
Brake Horsepower | 37 BHP |
Dimension | 2400 x 1030 x 1410 mm (L x B x H) |
Cooling System | Liquid Cooling |
Engine Model | G25-II |
Aspiration | TCIC |
Other Essentials:
Engines are tested as per BS5514, IS: 10002 and IS01000B respectively.
Superior quality alternators are used confirming to lS13364, IS4722 & BS5000 standards.
Technologically advanced control panels with Deep-sea / Procom controller. Heavy, robust and sound efficient DG sets confirming to CPCB-II norms & Rule 95 of environment protection of GSR no of 771(E) & GSR 232(E).
How to Calculate Load:
Put on only those equipment's which you want to run on the Powerlux Silent Generator.
Go near the distribution box where you'll find four colored cables; Red, Yellow, Blue & Black.
Put the clamp meter around the Red, Yellow & Blue cable one by one and note down the ampere rating.
Now add the numbers in case of single phase requirement or pick the highest in case of three phase requirement.
Select your kVA from the above given ampere chart and see under which rating your requirement falls.
Note:
After putting the clamp meter around the cable; turn off and on the heavy machines/equipment's for better calculation. Also always select a rating 20% higher to your load for long term usage.
AII of the above silent genset range is made to perform at 1500 rpm.
Rated current output is at 100% load.(0.8 Power Factor).
Weight mentioned is approximate.
Product innovation is a continuous process; hence data given is subject to change without any prior notice.
Detailed technical specification sheet separately available for each rating in soft copy.
Approx. Rs 6 Lakh / PieceGet Latest Price
Product BrochureProduct Details:Usage/Application | Industrial |
Power (kVA) | 10 kVA/8 KW |
Brand | Escorts Powerlux |
Model | ELG 10 (DG Model ) |
Phase | Three Phase |
Output Voltage | 415 V |
Fuel Consumption (at 100% Load) | 0.8 Power Factor |
Fuel Tank Capacity | 80 L |
Brake Horsepower | 18 BHP |
Material | MS |
Rated Current | 43 Amps at 230 V, 14 Amps at 415 V |
Cooling System | Liquid Cooling |
Engine Model | G12-II |
No Of Cylinders | 2 |
Speed | 1500 rpm |
Aluminium Cable | 2C-25/3.5C-16 Sq. mm. |
Dimension | 1530 x 930 x 1160 mm (L x B x H) |
Aspiration | Natural |
Weight | 655 Kg |
Noise Level | Silent or Soundproof |
Other Essentials:
Engines are tested as per BS5514, IS: 10002 and IS01000B respectively.
Superior quality alternators are used confirming to lS13364, IS4722 & BS5000 standards.
Technologically advanced control panels with Deep-sea / Procom controller. Heavy, robust and sound efficient DG sets confirming to CPCB-II norms & Rule 95 of environment protection of GSR no of 771(E) & GSR 232(E).
How to Calculate Load:
Put on only those equipment''s which you want to run on the Powerlux Silent Generator.
Go near the distribution box where you''ll find four colored cables; Red, Yellow, Blue & Black.
Put the clamp meter around the Red, Yellow & Blue cable one by one and note down the ampere rating.
Now add the numbers in case of single phase requirement or pick the highest in case of three phase requirement.
Select your kVA from the above given ampere chart and see under which rating your requirement falls.
Note:
After putting the clamp meter around the cable; turn off and on the heavy machines/equipment''s for better calculation. Also always select a rating 20% higher to your load for long term usage.
AII of the above silent genset range is made to perform at 1500 rpm.
Rated current output is at 100% load.(0.8 Power Factor).
Weight mentioned is approximate.
Product innovation is a continuous process; hence data given is subject to change without any prior notice.
Detailed technical specification sheet separately available for each rating in soft copy.
Approx. Rs 9 Lakh / PieceGet Latest Price
Product BrochureProduct Details:Power (kVA) | 15 KVA/12 KW |
Brand | Escorts Powerlux |
Model | ELG 15 (DG Model ) |
Phase | Three Phase |
Output Voltage | 415 V |
Fuel Tank Capacity | 130 L |
No Of Cylinders | 2 |
Dimension | 2100 x 930 x 1400 mm (L x B x H) |
Engine Model | G15-II |
Rated Current | 66 Amp at 230 V, 21 Amp at 415 V |
Brake Horsepower | 23 BHP |
Weight | 700 Kg |
Cooling System | Liquid Cooling |
Fuel type | Diesel |
Aspiration | Natural |
Other Essentials:
Engines are tested as per BS5514, IS: 10002 and IS01000B respectively.
Superior quality alternators are used confirming to lS13364, IS4722 & BS5000 standards.
Technologically advanced control panels with Deep-sea / Procom controller. Heavy, robust and sound efficient DG sets confirming to CPCB-II norms & Rule 95 of environment protection of GSR no of 771(E) & GSR 232(E).
How to Calculate Load:
Put on only those equipment''s which you want to run on the Powerlux Silent Generator.
Go near the distribution box where you''ll find four colored cables; Red, Yellow, Blue & Black.
Put the clamp meter around the Red, Yellow & Blue cable one by one and note down the ampere rating.
Now add the numbers in case of single phase requirement or pick the highest in case of three phase requirement.
Select your kVA from the above given ampere chart and see under which rating your requirement falls.
Note:
After putting the clamp meter around the cable; turn off and on the heavy machines/equipment''s for better calculation. Also always select a rating 20% higher to your load for long term usage.
AII of the above silent genset range is made to perform at 1500 rpm.
Rated current output is at 100% load.(0.8 Power Factor).
Weight mentioned is approximate.
Product innovation is a continuous process; hence data given is subject to change without any prior notice.
Detailed technical specification sheet separately available for each rating in soft copy.
Approx. Rs 7 Lakh / PieceGet Latest Price
Product BrochureProduct Details:Power (kVA) | 40 KVA /32 KW |
Brand | Escorts Powerlux |
Model | ELG 40 (Dg Set Model ) |
Phase | Three Phase |
Output Voltage | 415 V |
Fuel Tank Capacity | 130 L |
Cooling System | Liquid Cooling |
No Of Cylinders | 4 |
Weight | 1000 Kg |
Dimension | 2700 x 1030 x 1450 mm (L x B x H) |
Noise Level | Silent or Soundproof |
Aspiration | TCIC |
Aluminium Cable | 2C-120/3.5C-50 Sq. mm. |
Fuel type | Diesel |
Rated Current | 174 Amp at 230 V,56 Amp at 415 V |
Brake Horsepower | 58 BHP |
Engine Model | G40-II |
Other Essentials:
Engines are tested as per BS5514, IS: 10002 and IS01000B respectively.
Superior quality alternators are used confirming to lS13364, IS4722 & BS5000 standards.
Technologically advanced control panels with Deep-sea / Procom controller. Heavy, robust and sound efficient DG sets confirming to CPCB-II norms & Rule 95 of environment protection of GSR no of 771(E) & GSR 232(E).
How to Calculate Load:
Put on only those equipment''s which you want to run on the Powerlux Silent Generator.
Go near the distribution box where you''ll find four colored cables; Red, Yellow, Blue & Black.
Put the clamp meter around the Red, Yellow & Blue cable one by one and note down the ampere rating.
Now add the numbers in case of single phase requirement or pick the highest in case of three phase requirement.
Select your kVA from the above given ampere chart and see under which rating your requirement falls.
Note:
After putting the clamp meter around the cable; turn off and on the heavy machines/equipment''s for better calculation. Also always select a rating 20% higher to your load for long term usage.
AII of the above silent genset range is made to perform at 1500 rpm.
Rated current output is at 100% load.(0.8 Power Factor).
Weight mentioned is approximate.
Product innovation is a continuous process; hence data given is subject to change without any prior notice.
Detailed technical specification sheet separately available for each rating in soft copy.
Approx. Rs 8 Lakh / PieceGet Latest Price
Product BrochureProduct Details:Power (kVA) | 30 KVA/24 KW |
Brand | Escorts Powerlux |
Model | ELG 30 (Dg Set Model ) |
Phase | Three Phase |
Output Voltage | 415 V |
Fuel Tank Capacity | 130 L |
Fuel type | Diesel |
Weight | 870 Kg |
Dimension | 2400 x 1030 x 1410 mm (L x B x H) |
Aluminium Cable | 2C-95/3.5C-35 Sq. mm. |
No Of Cylinders | 3 |
Rated Current | 130 Amp at 230 V, 42 Amp at 415 V |
Cooling System | Liquid Cooling |
Brake Horsepower | 46 BHP |
Aspiration | TCIC |
Engine Model | G30-II |
Approx. Rs 7 Lakh / PieceGet Latest Price
Product BrochureProduct Details:Power (kVA) | 35 KVA/28 KW |
Brand | Escorts Powerlux |
Model | ELG 35 |
Phase | Three Phase |
Output Voltage | 415 V |
Fuel Tank Capacity | 130 L |
Cooling System | Liquid Cooling |
Engine Model | G40-II |
No Of Cylinders | 4 |
Weight | 945 Kg |
Brake Horsepower | 58 BHP |
Noise Level | Silent or Soundproof |
Rated Current | 152 Amp at 230 V, 49 Amp at 415 V |
Fuel type | Diesel |
Dimension | 2700 x 1030 x 1450 mm (L x B x H) |
Other Essentials:
Engines are tested as per BS5514, IS: 10002 and IS01000B respectively.
Superior quality alternators are used confirming to lS13364, IS4722 & BS5000 standards.
Technologically advanced control panels with Deep-sea / Procom controller. Heavy, robust and sound efficient DG sets confirming to CPCB-II norms & Rule 95 of environment protection of GSR no of 771(E) & GSR 232(E).
How to Calculate Load:
Put on only those equipment's which you want to run on the Powerlux Silent Generator.
Go near the distribution box where you'll find four colored cables; Red, Yellow, Blue & Black.
Put the clamp meter around the Red, Yellow & Blue cable one by one and note down the ampere rating.
Now add the numbers in case of single phase requirement or pick the highest in case of three phase requirement.
Select your kVA from the above given ampere chart and see under which rating your requirement falls.
Note:
After putting the clamp meter around the cable; turn off and on the heavy machines/equipment's for better calculation. Also always select a rating 20% higher to your load for long term usage.
AII of the above silent genset range is made to perform at 1500 rpm.
Rated current output is at 100% load.(0.8 Power Factor).
Weight mentioned is approximate.
Product innovation is a continuous process; hence data given is subject to change without any prior notice.
Detailed technical specification sheet separately available for each rating in soft copy.
Approx. Rs 5 Lakh / PieceGet Latest Price
Product BrochureProduct Details:Power (kVA) | 20 KVA/16 KW |
Brand | Escorts Powerlux |
Model | ELG 20 (Dg Set Model ) |
Phase | Three Phase |
Output Voltage | 415 V |
Fuel Tank Capacity | 130 L |
No Of Cylinders | 3 |
Aspiration | Natural |
Cooling System | Liquid Cooling |
Material | MS |
Rated Current | 87 Amps at 230 V, 28 Amps at 415 V |
Weight | 812 Kg |
Dimensions | 2300 x 930 x 1400 mm (L x B x H) |
Noise Level | Silent or Soundproof |
Brake Horsepower | 27.6 BHP |
Engine Model | G20-II |
Aluminium Cable | 2C-50/3.5C-16 Sq. mm. |
Other Essentials:
Engines are tested as per BS5514, IS: 10002 and IS01000B respectively.
Superior quality alternators are used confirming to lS13364, IS4722 & BS5000 standards.
Technologically advanced control panels with Deep-sea / Procom controller. Heavy, robust and sound efficient DG sets confirming to CPCB-II norms & Rule 95 of environment protection of GSR no of 771(E) & GSR 232(E).
How to Calculate Load:
Put on only those equipment's which you want to run on the Powerlux Silent Generator.
Go near the distribution box where you'll find four colored cables; Red, Yellow, Blue & Black.
Put the clamp meter around the Red, Yellow & Blue cable one by one and note down the ampere rating.
Now add the numbers in case of single phase requirement or pick the highest in case of three phase requirement.
Select your kVA from the above given ampere chart and see under which rating your requirement falls.
Note:
After putting the clamp meter around the cable; turn off and on the heavy machines/equipment's for better calculation. Also always select a rating 20% higher to your load for long term usage.
AII of the above silent genset range is made to perform at 1500 rpm.
Rated current output is at 100% load.(0.8 Power Factor).
Weight mentioned is approximate.
Product innovation is a continuous process; hence data given is subject to change without any prior notice.
Detailed technical specification sheet separately available for each rating in soft copy.
Explore More Products
© KRS Heavy Equipment Services. All Rights Reserved (Terms of Use)
Developed and Managed by IndiaMART InterMESH Limited